Alphabeta Math
ExampleConstruction: AI-generatedVerification: AI-generatedPipeline-generatedprecheck passverified 2026-10-22 (gpt-6.1-sol)
How statement and proof provenance work

The first chip identifies the source of the statement or construction; the second identifies the source of its local proof or verification.

  • Literature-sourced: the exact statement appears in a cited source; only wording and notation differ.
  • AI-adapted: a semantically identical restatement of literature-sourced material, modulo indexing, notation, and boundary cases adopted by the library.
  • AI-generated: a genuinely novel statement formulated by AI, with no source for the claim itself.

These labels describe origin, not correctness: citations and verification chips remain separate evidence.

Zeroth-order hydrostatic data do not determine bulk viscosity

Physical scope

Conditional comparison of two constitutive model instances sharing one hydrostatic pressure functional; no solution existence, empirical response, or universal transport claim.

Example

Suppose an application supplies a shared thermodynamic state map on which the pressure in the static hydrostatic functional equals the equilibrium pressure used by the local dissipative constitutive branch. At a common admissible local input with nonzero expansion θ, fix any ζ∗>0 in pascal-seconds and compare two model instances that agree on all hydrostatic data and use constant bulk-viscosity coefficients ζ1=ζ∗ and ζ2=2ζ∗. The bulk-viscosity coefficient here is the coefficient ζ multiplying the expansion in Π=−ζcθ; θ=∇aua is the expansion of the stated observer field. Their adopted hydrostatic functionals are identical, while their bulk-pressure corrections differ by Π2−Π1=−ζ∗cθ≠0. This difference has units of pressure. Thus hydrostatic data alone do not fix the bulk viscosity. This is a conditional comparison of constitutive maps; it asserts neither a solution of the balance equations nor an empirical response.

Facts & Assumptions

Given: Common hydrostatic data and the same pressure function in both model instances; a common admissible local constitutive input with θ≠0; and a constant ζ∗>0 in Pa s.

[F1]

Restricted hydrostatic effective functional: the adopted Whs depends on the static data and pressure function p(T,μ), and contains no bulk-viscosity coefficient.

[F2]

Restricted gradient constitutive dissipative model: the constitutive formula includes the bulk-pressure correction Π=−ζcθ.

[F3]

Restricted gradient constitutive dissipative model: θ=∇aua is the expansion of the smooth future unit observer field.

[F4]

Restricted gradient constitutive dissipative model: θ has inverse-length units, c>0 is in metres per second, ζ is in pascal-seconds, and Π is in pascals.

[A1]

The state-map identification between the pressure in the hydrostatic functional and the equilibrium pressure of the dissipative branch is an additional application-specific assumption for this comparison.

[A2]

Both constitutive maps are evaluated at the same admissible local input with θ≠0; no global solution of the balance equations is assumed.

Verification

1.1givenF1A1algebra

The two instances have the same T0,μ0,h,N,Φ,q and p(T,μ) by [A1]. The formula in [F1] therefore has exactly the same integrand and integration measure for both instances; changing ζ does not alter Whs.

1.2givenF2F3F4A2algebra

The constants ζ1=ζ∗ and ζ2=2ζ∗ are C1 and nonnegative because ζ∗>0. By [F2], at the common input in [A2] their corrections satisfy Π2−Π1=−(2ζ∗)cθ−(−ζ∗cθ)=−ζ∗cθ, which is nonzero since ζ∗,c>0 and θ≠0; θ has the definition in [F3] and the units are pascals by [F4].

2.1step 1.1step 1.2A1A2∎

Thus the same hydrostatic functional is compatible with two distinct bulk-pressure responses under the declared constitutive assumptions, so the functional alone does not identify ζ. This conclusion is conditional on the stated model identification and local input; it is not a claim about a measured fluid or an actual solution.

Depends on

Dependency tree · 2 levels

Sources