Reported stored-lithium-ion Ives-Stilwell Doppler experiment at 0.338c (2014)

Physical scope

Primary report of optical-optical double resonance spectroscopy of stored metastable 7Li+ ions in the ESR interaction section, with nominal speed beta = 0.338, calibrated laser frequencies, active-transition invariance and resonance-model auxiliaries. Describes a measured estimate and source-labelled standard uncertainty, not exact frequencies, a hard true-value bound, guaranteed coverage, raw data, or validation of every SR postulate. Atomic spectroscopy, real line widths, beam dynamics and calibration are empirical apparatus auxiliaries, not deductions from the ideal-plane-wave postulate.

Setup

Quantities and apparatus notation. The laboratory speed parameter is β=v/c, with v the selected ion-class speed in an approximately inertial laboratory description; its quoted value is nominal. Frequencies ν1,ν2,νp,νa>0 are scalar estimates in hertz of the two rest transitions and the parallel/antiparallel laser readings, respectively; the ideal-model convention is ν=ω/(2π) and λ=c/ν from Null wave covectors, frame frequency data and the observer frequency of an ideal plane wave, while the real apparatus has finite-width spectra. Here MHz=106 s−1, nm=10−9 m, and μrad=10−6 radians. For a single-peaked nonnegative profile, its full width at half maximum (FWHM) is the separation of the two frequencies (or speeds) at half its peak height, when those crossings exist; the reported δv/v uses the speed width divided by the selected speed. Beam divergence and alignment are angles between ion trajectories and the specified beam axis. A Lambda system here means three source-labelled atomic levels, two lower and one common upper, with the two listed driven transitions; the symbols 3S1, 3P2 and F distinguish the report's atomic levels, rather than supplying a quantum-state model. Metastable lifetime means the reported characteristic persistence time of the prepared level; no survival distribution is inferred. The Penning source, ESR (Experimental Storage Ring), electron cooling, lasers and optics below are the report's named preparation and control apparatus; their performance is reported empirically, not derived from SR. The energy label MeV/u is energy per atomic-mass unit: 1 MeV=106 electronvolts, with one electronvolt the energy acquired by elementary charge across one volt; it is not used here to deduce the nominal speed.

The experiment used 7Li+ ions from a Penning ion gauge source, accelerated to 58.6 MeV/u and stored in the ESR at nominal β=0.338. Electron cooling reduced the reported longitudinal velocity spread to δv/v≈9×10−6 (FWHM) and transverse divergence to less than 100 μrad. About 107 to 108 ions were stored, with an estimated metastable fraction below 1%. The metastable 3S1 lifetime was 15–30 s in the ring, compared with 50 s in vacuum. The Lambda system used the transitions 3S1(F=3/2)→3P2(F=5/2) and 3S1(F=5/2)→3P2(F=5/2). Parallel and antiparallel beams near 386 nm and 780 nm addressed its two legs; an additional 780 nm beam repumped ions into the system.

Procedure

Count and fit objects. A spectrum in this account is a finite list of frequency settings fi∈R with detected pulse counts ni,h∈N0 in each switching configuration h∈{1,2,3,4} and window. Fluorescence denotes the emitted light counted by the photomultipliers; a dark count is a registered pulse without applied excitation. Subtracted or averaged spectra are real-valued lists, not nonnegative integer counts or independent trials. A Lorentzian peak plus linear background means a fitted function L:R→R of the form L(f)=A/[1+4(f−f0)2/w2]+b0+b1(f−f0) with A>0, w>0; f0,w have frequency units, and the peak term has half height at f0±w/2. Residuals are the differences of processed values and the fitted values at the recorded settings. A weighted average of fitted centers has form ∑iwif0,i/∑iwi for nonnegative weights with positive sum; the report does not give the weights or their construction. Frequency locking means controlling a laser reading relative to a specified reference or offset; second-harmonic generation denotes conversion to twice the optical frequency. Optical-optical double resonance is the selected condition that both listed transitions are resonant for the same ion velocity class; it is an apparatus selection model, not a measured probability law.

The parallel beam was generated by doubling a 772 nm Ti:Sa laser locked to an iodine marker previously calibrated with a frequency comb against a rubidium clock. The antiparallel diode laser was offset-locked to a rubidium reference, with a 600 MHz tuning range. Polarization-maintaining fibers transported the beams. Motorized stages controlled angles and positions to 20 μrad and 50 μm; scrapers established laser/ion overlap within 80 μrad. Photomultipliers counted fluorescence in four successive 100 μs configurations: both excitation beams, antiparallel only, parallel only, and neither. Dark counts were subtracted, then the separate-beam background was subtracted from the both-beam spectrum. Optical-optical double resonance selected ions for which both Lambda legs were resonant at the same velocity. To compensate metastable depletion, an 81-point scan was paused after 69 points for injection and cooling. Figure 2 shows an example averaged over 44 scans, with 49 MHz laboratory linewidth and 35 MHz rest-frame linewidth. The authors fitted 40 spectra with Lorentzians on linear backgrounds and formed a weighted average. Raw count tables, fit weights, a covariance matrix and a complete likelihood are not published in this report.

Observations

Table I gives the frequency estimates, in MHz, ν1=546455143.0, ν2=546474960.7, νa=384225534.98 and νp=777210326.98. The rest-frame inputs ν1,ν2 come from earlier measurements cited as references 21–22; those papers were not retrieved or read here. Equation (4) reports ϵ=νaνp/(ν1ν2)−1=(1.5±2.3)×10−9 at nominal β=0.338. These are estimates with the source-labelled 1σ uncertainty budget, not exact values or guaranteed bounds. The rounded Table I centers yield approximately 1.4744849565×10−9, consistent with the reported rounded estimate, without reconstructing unrounded data.

Uncertainty

The Gouy phase is the additional spatial phase of a focused beam relative to a plane-wave phase; for a C1 phase correction ψ:J→R on a proper-time interval J⊆R, the phase-reading convention assigns a frequency correction −(2π)−1dψ/dτ under the stipulated phase-reading interpretation. No beam profile ψ is reconstructed here. The 1σ notation below is the source's label for an uncertainty scale; without its full estimation model it specifies neither a guaranteed interval nor a sampling distribution.

Table I labels its uncertainties 1σ. In MHz, the aggregate entries are 0.43 for each rest frequency, 1.6 for the antiparallel frequency and 1.25 for the parallel frequency. Antiparallel contributions are: weighted-fit statistical uncertainty 0.6, rubidium reference 0.05, diode stabilization 0.64, background linearization 0.5, Gouy phase 1.0, angular alignment 0.6, and ion divergence 0.4. Parallel contributions are: iodine reference 0.06, Ti:Sa stabilization 0.12, Gouy phase 1.0, alignment 0.6, and divergence 0.4. The inferred Gouy correction for each laser was 0.44±1.0 MHz, from experimentally validated numerical simulation using measured beam parameters. The authors reported no significant residual asymmetry; simulated background linearization was assigned 0.5 MHz. The excess linewidth, about five times the expected width, was attributed mainly to drift-induced fluorescence. The 0.6 MHz statistical entry comes from the weighted analysis of forty fitted spectra, not forty independent raw clock readings. These reported statistical and systematic scales are preserved without inventing independence, a Gaussian total sampling law, fit weights, covariance or coverage.

Interpretation

The measured observable tests the combined Doppler/time-dilation, active atomic-transition and vacuum-wave invariance assumptions together with resonance selection, calibration, beam alignment and correction models. The source reports no resolved deviation at its uncertainty level and quotes ∣α∣≤2.0×10−8 for α=ϵ/β2. That quotation is recorded as the source's test-theory sensitivity statement, rather than a newly certified hard bound or confidence interval. RMS and SME parameter translations and future higher-boost prospects remain contextual research topics; they are not prerequisites or claims of the comparison theorem.