How statement and proof provenance work
The first chip identifies the source of the statement or construction; the second identifies the source of its local proof or verification.
- Literature-sourced: the exact statement appears in a cited source; only wording and notation differ.
- AI-adapted: a semantically identical restatement of literature-sourced material, modulo indexing, notation, and boundary cases adopted by the library.
- AI-generated: a genuinely novel statement formulated by AI, with no source for the claim itself.
These labels describe origin, not correctness: citations and verification chips remain separate evidence.
Qualified reported anomaly by exact affine subtraction
Exact affine derivation from the 2022 reported one-electron Penning-trap estimate. The anomaly inherits the source's apparatus, correction, 11-field weighting, stated 1 sigma uncertainty, correlation caveat, and omitted-data limitations; no theory comparison or new statistical inference is made.
Statement
Let the source-reported dimensionless ratio be denoted , where is the Bohr magneton, with the elementary-charge magnitude in coulombs, the reduced Planck constant in joule-seconds, and the electron rest mass in kilograms, as specified in Fan2022 reported electron magnetic-moment determination. The hat marks an empirical estimate, not an exact constant. Define the derived dimensionless anomaly estimate . Under the empirical premise from Fan2022 reported electron magnetic-moment determination, whose reported central value is , exact subtraction gives The source-stated uncertainty remains , and all apparatus, correction, weighting, correlation, and source-data qualifications of the experiment remain in force. This is only an affine transformation of a reported estimate; it supplies no comparison with a theoretical prediction.
Facts & Assumptions
Given: The empirical premise and its reported qualifications in Fan2022 reported electron magnetic-moment determination.
Fan2022 reported electron magnetic-moment determination: the authors report as the weighted average of eleven corrected field determinations; they state a uncertainty of and note correlated nearby-field cavity uncertainties. The report's raw trials, covariance matrix, and weights are not reconstructed here.
The reference value in is exact and dimensionless.
Proof
Given: [F1], [A1], and the definition of in the Statement.
Subtracting the exact reference gives .
If the reported ratio is shifted from its central value by any deviation , subtracting the same exact leaves that deviation unchanged. Therefore the source-stated uncertainty remains , with the same measurement conditions, correction, weighting, correlation caveat, and omitted raw-data limitations from [F1]. No sampling distribution or theory comparison is introduced.