How statement and proof provenance work
The first chip identifies the source of the statement or construction; the second identifies the source of its local proof or verification.
- Literature-sourced: the exact statement appears in a cited source; only wording and notation differ.
- AI-adapted: a semantically identical restatement of literature-sourced material, modulo indexing, notation, and boundary cases adopted by the library.
- AI-generated: a genuinely novel statement formulated by AI, with no source for the claim itself.
These labels describe origin, not correctness: citations and verification chips remain separate evidence.
Specified-model comparison with calibrated bounds and reported uncertainty scales
General finite calibrated/nuisance model comparison and exact positive-frequency bound propagation, with separate source-reported-estimate/standard-uncertainty score analysis. Instantiates the actual 2014 stored 7Li+ optical-optical double resonance report under explicit atomic, optical, resonance and beam-calibration auxiliaries. Hard-bound declarations are conditional; reported 1-sigma scales imply no guaranteed bounds or coverage. No p-values, confidence levels, raw-data reanalysis or unique validation of SR are asserted. The comparator Gamma=1 is explicitly specified and evaluated at the nominal beta; all source empirical conditions and uncertainties are inherited.
Statement
Adopt Operational model, data, calibration and uncertainty vocabulary of the experiment interface. Comparison labels below range over explicitly specified prediction hypotheses, each with its own apparatus and calibration assumptions. When a label is an operational model of the SR framework, its prediction map must satisfy clause (b), condition , of that vocabulary using the specified SR suppliers. A competing prediction hypothesis need not be an SR operational model and is not represented as satisfying . Reported standard uncertainties are a separate record type, not the vocabulary's declared hard-bound records.
(a) General finite comparison. An apparatus/calibration nuisance parameter means an additional declared model input constrained together with the physical parameter; its domain is part of the admissible set below, and no probability law is implicit. Flatten a finite -dimensional record with entries to real coordinates. For each label , let be a declared set of admissible tuples , where is a physical parameter, an apparatus or calibration nuisance parameter, and an additive calibration correction. Let be its corrected prediction, ; every correction and admissibility constraint is explicitly stated. For a declared hard-bound record put and . Then if and only if . If the true calibrated vector satisfies the declared bounds and a candidate with its auxiliaries assigns that vector the value for some , then . Thus excludes that conjunction of candidate, parameter, calibration and hard-bound assumptions, rather than proving another model. If every prediction in has coordinate in disjoint from , then . This criterion is sufficient; overlap of marginal intervals alone does not establish joint feasibility.
(b) Exact finite uncertainty propagation. For positive frequencies define . If separately declared hard bounds place these frequencies in positive closed intervals , , and , then
Both endpoints are attained on this rectangular input domain. This is conditional on the hard-bound event; standard-uncertainty entries alone assert neither that event nor probabilistic independence.
(c) Reported-estimate comparison. A reported-estimate record consists of a finite real estimate vector, strictly positive reported scale entries , bibliographic and run annotations , and a source description of estimation and uncertainty construction. It asserts no hard bound or coverage. Here for and for ; a nonempty finite maximum is obtained by recursively comparing pairs. For a declared multiplier define
Then . This is a deterministic comparison of estimates and reported scales. No probability, -value, confidence level or rejection error rate follows without a separately justified sampling and error model.
(d) Primary-report instantiation. Under the qualified conditions of exp-sr-stored-lithium-ion-doppler-time-dilation-2014, additionally stipulate that resonance identifies each laser frequency in the ions' instantaneous rest frame with its stated rest transition frequency, that those transition frequencies are unchanged under active boosts, and that the ideal vacuum phase and frequency law applies in the interaction section after the report's beam, Gouy-phase and line-shape corrections. These atomic, optical and apparatus premises are not derived by Doppler shift and aberration for an ideal plane wave between inertial descriptions. At each selected reception event, additionally represent the ion by an inertial rest observer with velocity , , in a laboratory inertial frame . This is a stipulated reception idealization in the interaction section, not an application of the supplier to an accelerating storage-ring worldline. For oppositely propagating laboratory waves, that theorem gives
Hence . To make that interpretation explicit, fix arbitrary positive model transition frequencies in hertz. For each take the chart , its rest vector , and laboratory frequencies , . Take covectors with laboratory components and and phases , . Let contain these waves, , reception event and the declared scalar parameters, with the two frames attached to the readings. Then , parameter map , and prediction give an operational model for under the stipulated resonance identification. The transition frequencies here are model parameters; this construction does not assert exact knowledge of the report's uncertain frequency values. Define the alternative prediction hypothesis by replacing the common factor in those resonance equations by , retaining the same directional factors and apparatus assumptions. It predicts . This deliberately alternative hypothesis is not an SR operational model and makes no claim to satisfy ; it is not identified with all classical physics.
For the source-reported dimensionless estimate and scale , the declared criterion gives , with descriptive scale band . At the report's nominal , one has , hence : that nominal alternative prediction fails this scale criterion. This is not a statistical significance claim. The speed is nominal, no calibrated speed uncertainty is supplied for this evaluation, and no distribution or coverage is inferred. The SR product prediction is independent of ; the alternative prediction depends on its declared value. Agreement of SR with the descriptive scale band tests the physical and apparatus conjunction within the report's uncertainty treatment; it neither proves SR nor uniquely identifies its auxiliary assumptions. All conclusions inherit the primary report's conditions, calibration dependence and statistical and systematic limitations.
Facts & Assumptions
Given: A finite-dimensional hard-bound record with nonnegative entries , a label with declared admissible set and corrected prediction , a reported-estimate record with , a declared multiplier , and the reported stored-lithium-ion experiment of Reported stored-lithium-ion Ives-Stilwell Doppler experiment at 0.338c (2014) with its nominal speed, frequencies, corrections and uncertainty budget.
The experimental-interface vocabulary: an operational model has subject to the declared interpretation ; a data record declares that each value lies in its closed box in the declared units and contains no probability space, sampling law, independence assumption, likelihood or coverage statement; and clause (f) makes a consistency or comparison claim a separate claim requiring an explicitly declared comparison rule (Operational model, data, calibration and uncertainty vocabulary of the experiment interface).
The reported primary experiment: equation (4) reports at nominal ; Table I gives , , and in MHz with source-labelled scales; the reported scales include fitting, reference, stabilization, background, Gouy-phase, alignment and divergence entries; the raw data, fit weights and covariance are not published; the observable tests the combined Doppler, atomic-transition and apparatus assumptions (Reported stored-lithium-ion Ives-Stilwell Doppler experiment at 0.338c (2014)).
Doppler theorem: for inertial charts whose transition is with , the same future null wave covector with frame- data has frame- data with , , and the rest observers of the two charts read and ; in the axis case this is the longitudinal factor (Doppler shift and aberration for an ideal plane wave between inertial descriptions).
Frequency conventions: the observer of four-velocity reads ; a future null wave covector has frame components with , (Null wave covectors, frame frequency data and the observer frequency of an ideal plane wave).
Adopted ideal plane-wave model: an ideal monochromatic vacuum wave is modeled by a dimensionless affine phase with future null wave covector, and an ideal observer receiving it reads (Adopted ideal plane-wave and frequency-reading model).
The boost and inverse preserve the Lorentz form, orientation and future cone (The passive Lorentz boost with parameter beta, The passive boost is a proper orthochronous Lorentz map with inverse B(-beta)); therefore the inverse-boosted basis gives the inertial chart by Inertial frames and inertial charts of the affine Minkowski model. Covectors with components , , , are future null by Frame data of a future null wave covector: the unique pair with (e), and is their affine phase by Affine phase functions and wave covectors on affine Minkowski space (a).
Rational power laws: and for and rational ; for rational the map is strictly increasing on the positive reals; and if then if and only if (Laws of rational exponents, Monotonicity of and of claim 2, Sign rules for products and monotonicity of multiplication claim 4).
Proof
By definition is the preimage under of the box , restricted to ; hence is nonempty exactly when some admissible tuple has corrected prediction inside the box, that is exactly when ; and if the declared true calibrated vector lies in and an admissible tuple reproduces it, that tuple lies in by the same membership. Thus an empty rules out the conjunction of the candidate, its parameter and calibration auxiliaries and the declared bounds, and says nothing about which conjunct failed, so it does not by itself establish a competing hypothesis; the box is well defined and nonempty because , and it is a singleton exactly when .
On the positive rectangle the function is increasing in and decreasing in , because multiplying an inequality by a positive number and dividing it by a positive number preserve it by [F5]; the numerator product is positive and the denominator product is positive, so the quotient is positive, and the strictly increasing positive square root of [F5] preserves the two resulting inequalities, which are exactly the displayed lower and upper bounds; the corner lies in the rectangle by the interval hypotheses and attains the lower endpoint, and the opposite corner attains the upper endpoint.
The scale score is a finite maximum over the coordinates, so holds exactly when for every ; because every is strictly positive, this is exactly for every by the order rules of [F5], which is exactly the statement that lies in the product of the closed intervals. Taking preimages gives , an identity of sets of admissible tuples; at it reduces to the preimage of the point , and no random variable, measure or probability model is involved.
For each admissible ion velocity with the two laser frequencies are read in the moving ion's instantaneous rest frame; the parallel and antiparallel waves propagate along , so the Doppler factor of [F3] is and respectively, and assigning the rest-frame readings the rest transition frequencies as stipulated gives and with ; multiplying, , because and by the definition of , so . For the operational model displayed in (d), [F6] makes the inverse-boosted basis an inertial frame and future unit timelike. The laboratory frequencies are positive since , and ; [F6] makes both covectors future null with the displayed affine phases. At event the two readings assigned by [F3] and [A1] equal and by construction. The sets are nonempty and the identity parameter map is surjective; is a run description of [F1], and its computed product gives , proving . The alternative hypothesis that keeps the same directional factors and replaces by one gives , and hence .
If for some coordinate every value of lies in an interval disjoint from , then no admissible tuple has prediction in , so by step 1.1; this disjointness criterion is sufficient and not necessary, since for instance the two-point prediction set has both coordinate projections meeting at while no point of it lies in that box, so overlap of the marginal projections alone does not establish the joint feasibility that requires, and nuisance and calibration constraints inside cannot be replaced by their coordinatewise projections.
For the reported dimensionless estimate and scale, and in the units of the report's record; the SR prediction has score by step 1.3, so zero lies inside the descriptive scale band . For the nominal we compute and the two exact positive comparisons ; taking positive square roots and reciprocals by [F5] gives , that is , so the alternative prediction exceeds the estimate and its score is , again by step 1.3 and the order rules of [F5]. Hence at the nominal speed the SR prediction meets the declared scale criterion while the explicitly specified alternative prediction fails it by a wide margin.
Collecting the steps: (a) is steps 1.1 and 2.1, (b) is step 1.2, (c) is step 1.3 and the identity , and (d) is steps 1.4 and 2.2 with the auxiliaries and qualifications displayed in the Statement. The comparison rules are exact conditional statements about declared hard bounds, declared admissible tuples and declared reported scales; they are not instantiated as hard bounds by the experiment's entries, they establish no -value, confidence level or rejection error rate, and they establish neither the truth of SR nor the uniqueness of its auxiliary assumptions; all conclusions inherit the experiment's apparatus, calibration, finite-sampling, correction, borrowed-rest-frequency and unpublished-covariance qualifications, and the speed used in the numerical evaluation is the report's nominal value without a calibrated speed uncertainty.
Depends on
Operational model, data, calibration and uncertainty vocabulary of the experiment interface
Reported stored-lithium-ion Ives-Stilwell Doppler experiment at 0.338c (2014)
Doppler shift and aberration for an ideal plane wave between inertial descriptions
Null wave covectors, frame frequency data and the observer frequency of an ideal plane wave
Adopted ideal plane-wave and frequency-reading model
Laws of rational exponents
Monotonicity of and of
Sign rules for products and monotonicity of multiplication
Inertial frames and inertial charts of the affine Minkowski model
The passive Lorentz boost with parameter beta
The passive boost is a proper orthochronous Lorentz map with inverse B(-beta)
Frame data of a future null wave covector: the unique pair with
Affine phase functions and wave covectors on affine Minkowski space
Dependency tree · 2 levels
Sources
- B. Crowell, Special Relativity, revision 2020-12-10 (author-published undergraduate textbook, 246 PDF pages; the author's lightandmatter.com page links this Archive upload); signature (+---) converted to (-+++) and c = 1 formulas restored to x^0 = c t; Sections 1.3 'Measurement' and 1.4 'The Lorentz transformation', pp. 23-31 and Sections 3.2-3.3 pp. 55-59 (the stretch factor as Doppler shift)
- D. Tong, General Relativity (Cambridge Part III course notes, 2019), author-hosted copy of the official Cambridge full PDF; Chapter 1 Sections 1.2.1-1.2.2 printed pp. 12-16 (proper time on p. 14): proper time along a particle's worldline and the aging comparison
- B. Botermann et al., Test of Time Dilation Using Stored Li+ Ions as Clocks at Relativistic Speed, arXiv:1409.7951v1 (2014), full five-page primary report; equations (1)-(4), Figures 1-2, Table I. Published Phys. Rev. Lett. 113, 120405 (2014).